cv4pve-diag works with sensible defaults. To change thresholds, turn optional checks on or off, or tune performance, pass a JSON settings file with --settings-file.

Three built-in profiles cover the common cases. Use them on execute — they go after the command — or as the starting point of a settings file:

Profile Option What it does For
Fast --fast Skips backup content, snapshots and LVM-thin metadata Quick scan of large clusters
Standard (default) The defaults below Daily checks
Full --full Also S.M.A.R.T. details, ZFS pool details, NVD CVE lookup (needs internet access) and Ok results Audits, full verification

A --settings-file always wins over --fast / --full.

create-settings writes settings.json in the current folder, with the defaults or with a profile, and prints the accepted values of TimeFrame and Consolidation:

cv4pve-diag create-settings # Standard
cv4pve-diag create-settings --fast # Fast
cv4pve-diag create-settings --full # Full

The file is plain JSON. Unknown fields are ignored and omitted fields keep their default, so a file can hold only what you change:

{
"Backup": { "RecentDays": 1 },
"Snapshot": { "MaxAgeDays": 14 },
"Cve": { "NvdEnabled": true }
}

Fields are listed below as Group.Field. Thresholds are pairs { "Warning": …, "Critical": … }: the check warns when the value reaches Warning and becomes critical when it reaches Critical (for the health score, when it falls below them). A level set to 0 is off; 0 / 0 turns the check off.

Field Default What it does
MaxParallelRequests 5 API requests run in parallel. Higher is faster but loads Proxmox VE and uses more memory — 5 to 15 is a reasonable range; 1 runs sequentially.
ApiTimeout 0 Per-request timeout in seconds; 0 keeps the default of about 100 s. Raise it on slow or high-latency clusters.
IncludeOkResult false Also report passing checks, with gravity Ok — for audit reports that must show what was verified. A few checks never report Ok: the S.M.A.R.T. attribute checks, LVM-thin metadata, WC0020, and any threshold set to 0/0.
Field Default What it does Check
Backup.Enabled true Reads the backup files on every storage. false skips that read and the checks below. —
Backup.MaxAgeDays 60 Warns about backup files older than N days (protected backups excluded). 0 turns it off. WG0019
Backup.RecentDays 7 Warns when a guest has no backup in the last N days. 0 turns it off. WG0020

Orphaned backup files (WS0003) are also found only when Backup.Enabled is on.

Field Default What it does Check
Snapshot.Enabled true Reads the snapshots of every guest (one API call per VM/CT). false skips all snapshot checks. WG0021, WG0022, WG0023, WG0024, WG0035
Snapshot.MaxAgeDays 30 Warns about snapshots older than N days. 0 turns it off. WG0023
Snapshot.MaxCount 10 Warns when a guest has more than N snapshots. 0 turns it off. WG0024
Field Default What it does Check
Storage.Threshold 70 / 85 Usage % of storages, of the node root filesystem, of node swap and of ZFS pools. WS0009/CS0009, WN0029/CN0029, WN0030/CN0030, WN0044/CN0044
Storage.Rrd — Written by create-settings but not used: storage checks read the current usage. —
Field Default What it does Check
Node.Cpu 70 / 85 CPU usage % over the RRD window. WN0027/CN0027
Node.Memory 70 / 85 Memory usage %. WN0038/CN0038
Node.Network 0 / 0 (off) Network throughput in bytes/s, in and out. WN0039/CN0039, WN0040/CN0040
Node.IoWait 10 / 25 Average CPU I/O wait % — a sign of a storage bottleneck. WN0028/CN0028
Node.HealthScore 70 / 50 Composite score, see health score. Lower is worse. WN0048/CN0048
Node.Rrd.Pressure.Cpu 40 / 70 PSI CPU: % of time at least one task was stalled (PVE 9.0+). WN0031/CN0031
Node.Rrd.Pressure.IoFull 10 / 30 PSI I/O full (PVE 9.0+). WN0032/CN0032
Node.Rrd.Pressure.MemoryFull 5 / 15 PSI memory full (PVE 9.0+). WN0033/CN0033
Node.Rrd.TimeFrame Day RRD window for the averages: Hour, Day, Week, Month, Year. —
Node.Rrd.Consolidation Average Average smooths peaks, Maximum catches them. —
Node.MaxVCpuRatio 4.0 vCPUs of the VMs on the node (running or stopped, templates and containers excluded) divided by its physical CPUs, above which the node is overcommitted. WG0036
Node.ConsolidationCpuThreshold 10.0 Current node CPU %… IN0003
Node.ConsolidationMemThreshold 20.0 …and current node RAM % both below these: the node could be consolidated. IN0003
Node.Smart.Enabled false Per-attribute S.M.A.R.T. checks — reallocated, pending, uncorrectable sectors, CRC errors, temperature. One extra API call per disk. WN0020–WN0022, CN0008, CN0009, WN0019/CN0019
Node.Smart.Temperature 55 / 65 Disk temperature °C. WN0019/CN0019
Node.Smart.SsdWearout 70 / 85 SSD life consumed %. Runs even when Smart.Enabled is off. WN0018/CN0018
Node.NodeStorage.ZfsDetail false Per-pool vdev state and I/O errors. One API call per pool. CN0012, WN0024, WN0025
Node.NodeStorage.LvmThinMetadata true LVM-thin metadata usage, fixed limits 90% / 95%. One API call per node. WN0026 / CN0026

Qemu (VMs) and Lxc (containers) have the same fields, with the same defaults.

Field Default What it does Check
Qemu.Cpu, Lxc.Cpu 70 / 85 CPU usage % over the RRD window. WG0025/CG0025
Qemu.Memory, Lxc.Memory 70 / 85 Memory usage %. WG0026/CG0026
Qemu.Network, Lxc.Network 0 / 0 (off) Network throughput in bytes/s, in and out. WG0027/CG0027, WG0028/CG0028
Qemu.HealthScore, Lxc.HealthScore 60 / 40 Composite score, see health score. Lower is worse. WG0032/CG0032
….Rrd.Pressure.Cpu 50 / 80 PSI CPU inside the guest (PVE 9.0+). WG0029/CG0029
….Rrd.Pressure.IoFull 20 / 50 PSI I/O full (PVE 9.0+). WG0030/CG0030
….Rrd.Pressure.MemoryFull 10 / 30 PSI memory full (PVE 9.0+). WG0031/CG0031
….Rrd.TimeFrame, ….Rrd.Consolidation Day, Average As for nodes. —
Field Default What it does Check
Cve.NvdEnabled false Looks up the CVEs that affect the installed pve-manager version in the NVD (National Vulnerability Database). Needs internet access; no API key. CN0042, WN0042
Cve.MinCvssScore 7.0 Ignores CVEs below this CVSS score; 0 reports everything (very noisy). Score ≥ 9.0 is Critical (CN0042), anything lower Warning (WN0042). —

The lookup covers Proxmox VE itself (cpe:2.3:a:proxmox:virtual_environment). For the Debian packages of the nodes run debsecan on each node: the Proxmox VE API does not expose the full list of installed packages.

Node score = 100 - (cpu% × 0.4 + ram% × 0.4 + disk% × 0.2)
VM/CT score = 100 - (cpu% × 0.5 + ram% × 0.5)

PSI checks are skipped on Proxmox VE before 9.0, where those values are always zero.

Production cluster, conservative

{
"Backup": { "RecentDays": 1, "MaxAgeDays": 30 },
"Cve": { "NvdEnabled": true, "MinCvssScore": 7.0 },
"Node": { "Smart": { "Enabled": true } }
}

Audit / compliance run

{
"IncludeOkResult": true,
"Cve": { "NvdEnabled": true, "MinCvssScore": 4.0 }
}

Lab / dev — silence noise

{
"Snapshot": { "MaxCount": 0, "MaxAgeDays": 0 },
"Backup": { "Enabled": false }
}

Slow or high-latency connection

{
"MaxParallelRequests": 2,
"ApiTimeout": 30,
"Node": { "Smart": { "Enabled": false }, "NodeStorage": { "ZfsDetail": false } }
}